Electrical and energy

Data Centre Critical Facilities Engineer job simulation

Procedures, change control and a UPS event in a live data hall: capacity, battery runtime, PUE and safe work.

Data Centre Critical Facilities Engineer job simulation
  • Free: days 1 to 5, about 8 h 20 min of tickets
  • Premium: days 1 to 20
  • Checked as you go
  • Reviewed 19 Oct 2026

The project

You join Tarnmoor Data Services Ltd (simulated company)

Tarnmoor Data Services Ltd (simulated company) is a data centre operator in Reading. You help its team deliver a project for Selwyn Analytics Ltd (simulated company), at Data hall DH-2, Tarnmoor Campus 1.

Tarnmoor Data Services runs data hall DH-2 for its tenants. You join the critical facilities team in week one, learn the hall's power and cooling limits, work out how long the batteries last, calculate the month's PUE and review a procedure before a rack is installed. Later, a utility dip leaves one UPS on battery, a tenant asks for three more racks, a vendor wants to skip a step at 04:40, a generator test is not what it seems and a leak alarm needs an honest message to the tenant.

The people in the story are roles, such as Lead Engineer, not real people.

What you will do

By the end you will have

  • Check rack, UPS and cooling capacity against the hall's limits
  • Work out battery runtime and PUE from real meter and UPS data
  • Review a method of procedure and refuse to skip a step
  • Handle a utility dip, a generator test failure and a leak alarm
  • Answer a tenant's capacity request honestly and in plain words

Day by day

The plan, ticket by ticket

Self-paced. A day opens when you hand in the previous day's tickets.
Data Centre Critical Facilities Engineer job simulation plan
DayTicketKindTimeEdition
1Induction: how a data hall stays up and how people stay safeQuiz35 minFree
2Safety walk and hall tour in the lab3D lab1 hFree
2Six racks: does each feed carry the rack alone?Table1 h 10 minFree
3How long can the batteries carry the hall?Calculation1 h 10 minFree
3PUE for the month from the metersCalculation1 hFree
4Review MOP-0042 Rev 2Document review1 h 20 minFree
5A wrong breaker, no harm done, and a request for silenceDecision30 minFree
5Write tonight's shift handover noteWriting50 minFree
5One more 10 kW rack: what does cooling say?Calculation45 minFree
6Incident report: the 02:14 utility dipWriting1 h 30 minPremium
7How much battery did the dip use, and how much was left?Calculation1 h 50 minPremium
8Impact note for CHG-0136: three racks of 15 kWWriting1 h 15 minPremium
9Re-run the capacity register for the requestCalculation2 hPremium
10Which documents move after accepting one rack?Table1 h 20 minPremium
11Review the vendor's MOP-0057 for UPS-BDocument review1 h 30 minPremium
1204:40: skip the final verify to beat the morning peak?Decision40 minPremium
13Fix a hot aisle in the lab3D lab1 h 15 minPremium
14Monthly generator test: pass or fail each checkTable1 h 20 minPremium
15Power event drill in the lab3D lab1 h 15 minPremium
16Written update to the tenant during a water leak alarmWriting1 h 10 minPremium
17Rack power budget in the lab3D lab1 h 15 minPremium
18Capstone: operational readiness pack for the row F rackHand-in4 hPremium
19Reply to the tenant: what can you give us?Writing1 hPremium
20Viva: your critical facilities decisionsViva40 minPremium

Real documents

The documents you will work with

Project documents
NumberDocumentRevEdition
DC1-SOP-001Site rules, safe work and change discipline3Free
DC1-SLD-001Power single-line diagram, hall DH-2 (A and B, 2N)4Free
DC1-CAP-001Capacity register, hall DH-25Free
DC1-CLG-001Cooling schematic summary and set-points2Free
DC1-UPS-001UPS and battery dataBFree
DC1-ALM-001Alarm list and escalation matrix2Free
DC1-MTR-001Energy meter readings, 30 days (720 hours)AFree
DC1-MOP-0042Install rack R-F01 and connect the A and B feeds2Free
DC1-EOP-UPS-03Emergency operating procedure: UPS on battery3Free
DC1-LOG-001Shift handover log: format and sampleAFree
DC1-INC-0211Event log: utility voltage dip at 02:14, hall DH-2APremium
DC1-CHG-0136Change request: tenant adds three racks of 15 kW in row F0Premium
DC1-MOP-0057Place UPS-B in maintenance bypass and replace power module PM-31Premium
DC1-GEN-001Generator and transfer switch monthly test logAPremium

Tools

In the industry, and here

In the industryHere
BMS and EPMS for power and coolingEvent logs, meter tables and the 3D data centre lab
DCIM capacity toolsThe capacity register and calculation fields
Change management tickets and MOP templatesMOPs, change requests and impact notes in the documents
Excel capacity modelsWorked calculations and your own working

Standards

The standards the work follows

  • TIA-942
  • Uptime Institute tier concepts
  • IEC 62040-3
  • ASHRAE TC 9.9
  • NFPA 70E (safe work practice)

Prepare

Labs and study materials

Free, and linked where a ticket needs them.

What you get

Free, certificate and Premium

Free

Days 1 to 5, every ticket checked, model answers, the 3D lab and a profile entry.

Free

Certificate (optional)

  • A graded, verifiable certificate with your score and band
  • A public verification page and QR code
  • One-click add to LinkedIn as a licence or certification
  • A Verified mark on your profile entry

₹499

Premium

Premium job simulation

  • The full four-week project: change requests, site work, faults and handover
  • A capstone deliverable reviewed by an engineer
  • An AI viva on your own work
  • The graded certificate and a work record PDF with your skill scores
  • Priority help from our team
₹1,499The certificate is included. If you bought it, its price is credited.

On your profile

How it shows on your profile

It shows on your EDWartens profile under Work experience, marked as a job simulation.

Work experience

Data Centre Critical Facilities Engineer (job simulation)

Tarnmoor Data Services Ltd (simulated company)

8 h 20 min active hours logged · Your dates

Verified, with the certificate

A job simulation is a realistic training project at a simulated company. It is not employment, an internship or a work placement. Hours are active hours the learner logged on EDWartens.

Questions

Quick answers

Do I need to know data centres already?

No. The documents teach what you need: 2N power, UPS runtime, PUE, MOPs and change control.

Which standards does it follow?

It follows the ideas of TIA-942, Uptime tier concepts, IEC 62040-3, ASHRAE TC 9.9 and NFPA 70E style safe work practice.

How long does the free week take?

About nine hours of active work over five working days.

What does the Premium edition add?

The full four-week project: the utility dip, the capacity request, a vendor MOP, the generator test and a leak alarm, a capstone pack reviewed by an engineer and an AI viva.

Is this a real job?

No. It is a job simulation at a simulated company. It is not employment.

Is the Data Centre Critical Facilities Engineer job simulation free?

Yes, to start. Days 1 to 5 are free. The certificate and the Premium edition are optional and are priced on this page in your currency.

Does it count as work experience?

It shows on your EDWartens profile under Work experience, marked as a job simulation. It is not employment. A job simulation is a realistic training project at a simulated company. It is not employment, an internship or a work placement. Hours are active hours the learner logged on EDWartens.